Gas turbine

Lubrication and control system, Combined Heat and Power Plant
System: ALSTOM GT8C2 gas turbine
Fuel: Natural gas
Power: 56 MW
Oil type: Shell Turbo CC 46
Oil volume: 30,000 litres

Challenge

Varnish deposits on the valves and bearings led to limited controllability of the gas turbine. Particularly during the heating period a flexible start of the gas turbine could not be guaranteed. The deposits were caused by a highly advanced oil degradation process resulting from thermal stress and oxidation of the oil.

Despite existing filter systems, the MPC value was 54.9. Due to this critical oil condition an oil change would have been unavoidable.

Valve with varnish (varnish-like deposits)
Valve with varnish —varnish-like deposits that limit controllability
ALSTOM GT8C2 Gas Turbine

ALSTOM GT8C2 Gas Turbine

CJC® Varnish Removal Unit Installed on a gas turbine

CJC® Varnish Removal Unit

Solution

A CJC® Varnish Removal Unit VRU 27/108 was installed. The CJC® VRU continuously removes varnish, particles, and water from the turbine lubricating oil.

Absorption capacity: Varnish approx. 8 kg / Dirt approx. 8 kg / Water approx. 8 litres
Filtration degree: 3 µm absolute, 1 µm nominal
Filter type/material: Depth filter made of 100% natural fibers

Roller Bearing, Gyratory Crusher, Overhaul, without CJC® Offline Oil Filter

Result

Due to the continuous fine filtration of the oil by the CJC® Varnish Removal Unit (VRU), the MPC value dropped to an uncritical level. The clean oil dissolves further contaminants and deposits from the system components, ensuring that an MPC value of < 10 is achieved over the long term and that flexible turbine operation is maintained. The oil continues to be used. Based on these convincing results, two steam turbines were also equipped with CJC® VRUs:

  • Siemens T8435 back-pressure steam turbine with
    9,000 litres of Mobil DTE 846
    Result here:
    MPC value improved from 59.2 to 9.9.
  • Siemens T6192 steam turbine with
    10,500 litres of Shell Turbo CC46
    Result here:
    MPC value improved from 32.8 to 7.8.
Improving the CO2 footprint

Further advantages:

Longer oil change intervals lead to high savings and, at the same time, protect the environment and resources:

  • less new oil
  • less waste oil, and CO2 —
    > 144 tons per oil change saved on the gas turbine alone *)
*) The thermal disposal of used oil produces approximately 4.8 kg of CO2 per litre.
Visual inspection: Oil inlet (left), oil outlet (right)

Visual inspection
Left: Oil inlet
Right: Oil outlet

MPC Patch without CJC® VRU

MPC Patch
WITHOUT CJC® VRU

MPC Patch with CJC® VRU

MPC Patch
WITH CJC® VRU

Oil samples – MPC test
, Membrane Patch Colorimetry

MPC test, gas turbine
Further information on MPC values are available on request.