Lube Oil Care Marine Diesel Engines (4-stroke) | Supply Vessel
Customer Case
Marine Diesel Engines
Vessel: Supply Vessel
Engines: BERGEN, 2,500 kW/750 rpm (2 pieces), 4-stroke diesel engines
Lube Oil: SHELL GADINIA AL 40
Test: Centrifuge vs. CJC® Lubricating Oil Filter
Test period: > 10,000 running hours
Test start: at 144,992 running hours
Test end: at 155,123 running hours
Conventional lubrication oil treatment:
One centrifuge (lubricating oil separator) per motor.
Flow rate: 550–810 litres/hr.
Newly installed CJC® lubricating oil filter:
During the test period, a CJC® 27/108 lubricating oil filter was installed on one of the two engines (ME 2) for continuous fine filtration and dewatering (24/7/365). The automatic, temperature-dependent control of the flow rate ensures maximum filter efficiency.
Pump flow: 1,150 L per hour (0.3 L/kW) nominal


Savings benefits
Approx. 97.5% lower energy consumption
≅ 229,774 kW/year and centrifuge
- ME 1 with centrifuge, energy requirement ≅ 235 ,468 kW (26.88 kW for operation + preheater)
- ME 2 with CJC® lubricating oil filter, power consumption ≅ 5 ,694 kW (0.65 kW during operation)
Approx. 97.8% less CO2 emissions
≅ 159,649 kg/year saved and one centrifuge eliminated
The combustion of 1 litre of diesel oil or the thermal disposal of 1 litre of waste oil or sludge produces approximately 2.6 kgof CO2.
Lower energy consumption:
- ME 1 with centrifuge ≅ 143,246 kg ofCO2
- ME 2 with CJC® lubricating oil filter ≅ 3,463 kg CO2*)
*) Based on consumption of approx. 187 g fuel per kWh.
Lower amount of sludge to be disposed of:
- ME 1 with centrifuge ≅ 19,929 kg ofCO2
- ME 2 with CJC® lubricating oil filter ≅ 62.4 kgCO2
Approx. 99.7% less sludge
≅ 7,641 litres/year per centrifuge
- ME 1 with centrifuge, discharge capacity ≅ 7,650 litres
- ME 2 with CJC® lubricating oil filter, filter change ≅ 24 litres
Approx. 60 % less lube oil consumption
≅ 8,940 litres/year per centrifuge
- ME 1 with centrifuge, discharge system, and motor ≅ 14,900 litres
- ME 2 with CJC® lubricating oil filter, filter replacement, and engine ≅ 5,960 litres
Approx. 60 % less working hours
≅ 8 hours per year per centrifuge
- ME 1 with centrifuge, estimated maintenance time ≈ 20 hours
- ME 2 with CJC® lubricating oil filter; maintenance time ≈ 12 hours
Approx. 86.25 % less operating costs
≅ 30,199 EUR/year and centrifuge
| Specific lube oil consumption (SLOC) at maximal continuous rate (MCR) |
||||
|---|---|---|---|---|
| Engine ME1 with lube oil separator |
Engine ME2 with CJC ® Lube Oil Filter |
|||
| SLOCMCR* [g/kWh] | 0,71 | 0,28 | ||
*) SLOC = Specific Lube Oil Consumption
MCR = Maximum Continuous Rating
| Savings | ||
|---|---|---|
| OPEX per year (359 working days, approx. 8,616 h/year) | Lube oil separator | CJC ® Lube Oil Filter |
| Oil costs [1,97 EUR/L] | 15,090 EUR | 48 EUR |
| Energiekosten [0,08 EUR/kWh] | 18,535 EUR | 465 EUR |
Disposal costs [0.12 EUR/L]
Sludge, filter inserts |
950 EUR | 120 EUR |
| Maintenance costs, expandable materials | 440 EUR | 4,183 EUR |
| Total costs | 35,015 EUR | 4,816 EUR |
| Total savings per year | 30,199 EUR | |
Contact your maritime technical salesperson now
You would like to know more about the customer case? Let us start a conversation
Receive detailed information on the oil analyses, savings and calculations and a personal consultation specifically on your 4-stroke diesel engine, your lube oil and your requirements and goals.
Write or call us.