Lube Oil Care 4-Stroke Diesel Engines | Container Vessel
Customer Case
Marine Diesel Engines
Vessel: Container vessel, 4,200 TEU
Engines: MaK 6M332, 2,880 kW/600 rpm
Running hours: 5,300 RHs/year
Load: Ø 60% part load, long periods with < 30%
Lubricating oil: 2,250 litres of SHELL ARGINA X 40 (0.8 litre/kW)
Fuel: 70% HFO 380–700 cSt, sulfur content: 2.5–3.5%; 30% MDO or LSHFO 80 cSt, sulfur content: < 0.1%

Test: Centrifuge vs. CJC® Lubricating Oil Filter
Test period: 17 months
Running hours: 7,880 RHs during test period
Test start: at approx. 25,000 RHs
Last revision: 13,680 RHs ago at test end
Conventional lubricating oil treatment:
One centrifuge for two engines (DG#1 and DG#2) and one centrifuge bypass filter (“Glacier Filter”) per engine.
Newly installed CJC® lubricating oil filter:
During the test period, a CJC® 3×27/108 lubricating oil filter was installed on Engine DG#1 for continuous depth filtration and dehydration (24/7/365). The automatic, temperature-dependent control of the flow rate ensures maximum filter efficiency.
Pump flow: 1,680 L per hour (0.58 L/kW) nominal, at test end 840 L per hour (0.29 L/kW)

Savings and Benefits
50–60% lower lube oil consumption
≅ 5,465 Litres per year
The specific lubricating oil consumption (SLOCMCR*) of the test engine with a CJC® lubricating oil filter installed is 0.25 g/kWh—0.31 g/kWh lower than that of the engine with a centrifuge:
- significant less oil consumption
- improved engine performance
Fewer deposits inside the engine
The dark, black deposits on the surfaces—a mixture of asphaltenes and soot—have clearly decreased on the test engine. The trial engine is much cleaner than the engine with the separator.
Good dipersant properties, low soot content
The test for quick analyses of oil and engine condition confirms that the lube oil of the trial engine has a lower soot content and better dispersant properties. The improved lubrication effect and the preservation of the oil’s properties extend the service life and durability of the lubricating oil.
Less sludge
During this process the thickness of the sludge layer precipitated in the filters is measured (ø 5 mm). Approximately 3,000 hours after the CJC® lubricating oil filter was installed, no sludge buildup was detected on the centrifuge bypass filter of the test engine.
| Specific lube oil consumption OEM specifications: SLOCMCR = 0.6 g/kWh (+/- 0.3) |
||||
|---|---|---|---|---|
| Engine DG#2 with a centrifuge |
Engine DG#1 with CJC® lubricating oil filters |
|||
| Running hours | 1.868 | 7.785 | ||
| Oil consumption [L] | 3.450 | 6.350 | ||
| SLOCMCR* [g/kWh] | 0,56 | 0,25 | ||
*) SLOC = Specific Lube Oil Consumption
MCR = Maximum Continuous Rating
Contact your maritime technical salesperson now
You would like to know more about the customer case? Let us start a conversation
Receive detailed information on the oil analyses, savings and calculations and a personal consultation specifically on your 4-stroke diesel engine, your lube oil care and your requirements and goals.
Write or call us.